Appendix A
110
Category: Startup
Action: Ensure the MOS ConfigService is started.
Error: MOS Gateway Logger cannot start: Cannot create
MOSConfiguration object.
Location: Event Log Source: MOS Gateway Logger
Category: Startup
Action: Ensure the MOS ConfigService is started.
Error: MOS Gateway Logger cannot start: Config file incomplete, the
<logging> group must include <directory>, <maxFileCount>,
and <maxFileBytes> elements."
Location: Event Log Source: MOS Gateway Logger
Category: Startup
Action: Open the MOS Gateway configuration file. Check that the
<logging> group has three lines with tags: <directory>,
<maxFileCount>, and <maxFileBytes>, each with a non-empty
value. Add one or more if necessary. Stop and restart the Router.
Error: MOS Gateway Logger cannot start: Configuration file not found
Location: Event Log Source: MOS Gateway Logger
Action: Open the Registry Editor and navigate to the key
HKEY_LOCAL_MACHINE\SOFTWARE\Avid Technology\
MOSGateway.